179
Three Phase TEFC Motors
Features:
• Ball Bearings
• Class F Insulation
• Continuous Duty
• Energy Efficient
$
• NEMA Design B
• Rigid Base
• Squirrel Cage
• Cast Iron
Applications:
Pumps, fans, compressors, conveyors, machine tools, designed to stand up to abusive treatment..moist, dirty, dusty and factory applications.
Full Load
Stock
Insul.
Cast
“C”
HP RPM
Volts
Amps
Frame
Number
Class Iron Type
Dim. Efficiency Notes
10
3600
200-230/460 25.5-23.0/11.5
215T
E8011
J
F
√ E+3(NP)
19.8 90.2
1,8,11
200-230/460 29.4-24.0/12.0
215T
T46007
J
F
E+
19.4 89.5 11,23,362,363
230/460
23.0/11.5
215T
T57007
J
F
√ E+3(NP)
19.4 90.2 11,362,363
575
9.2
215T
E367
J
F
E+
19.5 89.5
1,11
575
9.6
215T
T48007
J
F
E+
19.4 89.5 11,363,365
575
9.2
215T
T59007
J
F
√ E+3(NP)
19.4 90.2 11,363,365
1800
200
28.3
215T
T44032
J
F
E+
19.4 89.5 11,363,365
New!
200
27.4
215T
T55032
J
F
√ E+3(NP)
19.4 91.7 11,363,365
New!
200-230/460 28.5-25.0/12.5
215T
E321
J
F
E+
19.9 89.5
8
200-230/460 28.0-25.0/13.0
215T
T46032
J
F
E+
19.4 89.5 11,23,362,363
230/460
23.8/11.9
215T
T57032
J
F
√ E+3(NP)
19.4 91.7 11,362,363
575
10.1
215T
T48032
J
F
E+
19.4 89.5 11,363,365
575
9.5
215T
T59032
J
F
√ E+3(NP)
19.4 91.7 11,363,365
1200
200-230/460 30.2-26.0/13.0
256T
E443
J
F
E+
24.9 89.5
1,11
200-230/460 32.2-28.0/14.0
256T
E8012
J
F
E+3
24.8 91.0
1,8,11
200-230/460 28.6-26.6/13.3
256T
T46057
J
F
E+
25.1 89.5 11,23,362,364
230/460
26.4/13.2
256T
T57057
J
F
√ E+3(NP)
25.1 91.0 11,362,364
575
10.5
256T
E435
J
F
E+
24.9 89.5
1,11
575
10.6
256T
T48057
J
F
E+
25.1 89.5 11,364,365
575
10.6
256T
T59057
J
F
√ E+3(NP)
25.1 91.0 11,364,365
Notes:
Continues on next page
  1. Item to be discontinued when stock is depleted
  8. NEMA Design A
 11. C flange kit available
23. Suitable for 200/400 Volt and 50 HZ
362. 12 lead – Capability for Y Start-Delta Run
363. Double shielded bearings with no regreasing provisions
364. Open bearings with regreasing provisions
365. 3 leads
Published efficiency on tri-voltage rated motors applies at 230/460 volts.
Performance at 200 or 208 volts may not be in accordance with NEMA standards.
Published efficiency on 200-208 volt motors applies at 200 volts.
• Standard, EPAct CC001A
(E-Plus
®
motors) and Premium
(E-Plus
®
3 motors) Efficiency
• Totally Enclosed
• 1⁄4 thru 400 HP
• 1.15 Service Factor
• 40°C Ambient
• 60 Hz
• 56 Frame and larger
• 3600, 1800 and 1200 RPM
• E-Plus
®
Motors meet the require-
ments of the Energy Policy Act of
1992. E-Plus
®
3 motors exceed the
requirements of the Energy Policy
Act of 1992.
E+3(NP) is NEMA
Premium Efficient.
Continued from previous page
Motors specially designed, tested and warranted to
be
Corona-Free
for compatible inverter duty are
marked on this page with a
J
. See page 4 and 5
of this catalog for more Speed Engineered
®
motors
information.
T46007